WebIn the venture meter, the area of the tube decreases gradually due to which the velocity increase to keep the flow rate constant. In the orifice plate, there is a sudden decrease …
Flow meter venturi lab report
Did you know?
WebFluid laboratory Flow Measurement Using Venturi Meter Asst.Lectuer: Mohammed Abid Jameel 1. Introduction: A Venturi meter is a tube with a constricted throat that increases velocity and decreases the pressure. Venturi meter is used for measuring the flow rate of both compressible and incompressible fluids in pipeline. For http://connectioncenter.3m.com/venturi+flume+lab+report
Webanalyze the features of certain meters. 3. THEORY . Figure 1. Flow measurement apparatus The flow measurement apparatus consists of a water loop as shown above figure. The supple line is connected to a gravimetric hydraulic bench. The flow rate controlled by a gate valve located at the discharge side of the hydraulics bench. A … WebCHE241 Fluid Mechanics- Lab Report Flowmeter Test Accessories (DOC) CHE241 Fluid Mechanics- Lab Report Flowmeter Measurement Apparatus Arif Hanafi - Academia.edu / 000844-0029 Ding 1 Physics Internal Assessment: Experiment ...
WebVenturi Meter1 Water Supply Flow meter Stop watch Calculator B. Procedure Let us first define the Venturi Meter and the way it works in order to proceed in the experiment: The … WebJun 19, 2024 · According to the formula, the flow rate can be calculated according to the following formula: where C v is the Venturi coefficient, A 1 and A 2 are the areas of the pipe cross-section, ΔP is the difference between the pressure in A 1 and A 2, and ρair us the density of air. Based on the conditions of the experiment, C v equals 0.8159.
WebAt this condition the maximum pressure difference between the venturi inlet and throat should be 240 millimeters. Observe the water levels for a few minutes to ensure the …
WebAlso, water from the Venturi meter will be flowing through the pipe into a tank that stands on a scale. There will be six runs conducted with different heights between the inlet and throat. Run 1: (hA – hD) = 10 inches Run 2: 8 inches Run 3: 6 inches Run 4: 4 inches Run 5: 2 inches Run 6: 0 inches The heights of each of the eleven piezometers ... chucks steaks and margaritacilleWebA stopwatch for timing the flow measurement. 6. Equipment Description. The Bernoulli test apparatus consists of a tapered duct (venturi), a series of manometers tapped into the venturi to measure the pressure head, and … chucks steak house menu myrtle beach scWebNov 12, 2024 · Flow Measurement Lab Report. Venturi meters consist of a short length of pipe with a portion with the least cross- sectional area, which fits into a normal pipe-line. … chucks store newburgWebFigure 2 shows an orifice meter with the variable position of vena contracta with respect to the orifice plate. By employing the continuity equation and Bernoulli’s principle, the volumetric flow rate through the orifice meter can be calculated as described previously for venturi meter. Hence, ¥ 3= 8 6 5 6= ¼ À Ì . ¥ 5 ? 0 chucks stockton caWebJan 16, 2014 · 10. PROCEDURE 1. REGULATE THE INLET VALVE TO ALLOW A STEADY FLOW THROUGH VENTURIMETER 2. COLLECT THE CERTAIN VOLUME OF WATER IN THE TANK AND NOTE THE TIME T 3. NOTE THE MANOMETER READING IN THE LEFT LIMB (H1) AND RIGHT LIMB OF MANOMETER (H2). THIS DIFFERENCE IS … des moines iowa weather 7-day forecastWebFluid Lab 4 - Prexams des moines is there crossword clueWebThis experiment use the Bernoulli‘s Theorem Demonstration Apparatus. The apparatus contains many parts which are venture meter, a pad of piezometer tube, pump, and water tank equipped with a pump water controller, water host, and tubes. This experiment uses the venturi meter to measure the fluid flow through a pipe. chucks steak house menu rocky hill ct